Specifications
|
ERR3700R20 |
| Efficiency (gr./lb. @ min. lb. salt dose) |
4,100 @ 2.4 |
| Hardness Capacity (gr. @ max. lb. salt dose) |
20,900 @ 8.9 |
| Certified Flow Rate (gpm @ psi) |
8 @ 7 |
| Intermittent Flow Rate (gpm @ psi) |
14.8 @ 15 |
| Intermittent Flow Rate (gpm @ psi) |
23.6 @ 30 |
| Stratified Resin Bed (lbs.) |
38 |
| Quartz Gravel Base (lbs.) |
10 |
| Maximum Water Hardness (grains per gallon) |
50 |
| Maximum Clear Water Iron (ppm-Fe) |
10 |
| Maximum Chlorine (ppm) |
4 |
| Approximate Water Used Each Regeneration (gal.) |
39 |
| Salt Storage Capacity (lbs.) |
200 |
| Supply Water Pressure Limits (psi) |
20-125 |
| Supply Water Temperature Limits (°F / °C) |
40-100 / 4-38 |
| Chlorine Taste and Odor Reduction (gallons at 1.0 ppm) |
1,460,000 |
| Ambient Temperature Range (°F / °C) |
35-150 / 2-66 |
| Plumbing Connection Provided (inches) |
1 |
Electrical Requirement, 120V, 50/60Hz, (24V DC, 500 mA, power supply included)
1Intermittent flow rate does not represent the maximum service flow rate used for determining the refiner’s rated capacity and efficiency. Continuous operation at flow rates greater than the certified flow rate
may affect capacity and efficiency performance. The validity of these flow rates is verified by NSF.
2When operated at 35 psi water pressure. 3Maximum pressure for Canadian use is 7.0 Kg/cm2.
4Typical residential chlorine concentration is 0.5 to 1.0 ppm.
5From independent laboratory test data.